technical data
Power consumption 24 V DC: 300 mA
Control function: Yes, Hi-O Technology
Operation and display function: Yes, integrated
Power supply: No, external power supply required
Connection: 4-wire bus cabling
Time delay: Yes (optional)
Illuminated indicator sign: Yes, through the integrated touch display
Display of release delay: Yes
Emergency stop switch: Yes, by operating the display unit
Control element: By code and function areas on the touch display
Commissioning: Configuration via integrated touch display
Required power supply: 24 V (±15 %) DC SELV
Operating temperature range: –10 °C – +55 °C
Application: For indoor use
Protection class: IP30 (when fully assembled)
Mounting: In switch boxes >= 62.5 mm deep
Dimensions: 113 x 99 x 29 mm (H x W x D)
Colour: Black (housing)
Inputs: 2
Outputs: None
Number of bus addresses: 3
Emergency door terminal for bidirectional escape route Yes
Tested according to EltVTR; DIN EN 13637:2015
Voltage (electric strike)
9 - 24 Volt