Assa Abloy ePED® Display Door Terminal 1386D10

Für die Anwendung mit und ohne Zeitverzögerung, mit 4 Draht-Bus-Verkabelung in Hi-O Technology. Ersetzt bisherige Fluchttür-Steuerungs-Systeme mit Komponenten aus Not-Auf-Auslösung, Schlüsselschalter

more details
Meesenburg Article Number: 0009257472
Manufacturer item no.: 1386D10------S0
EAN: 4042203706637
Verkaufseinheit
x
Quantity:
=
measurement_units.standard.ST.name
Online availability
Location availability
Availability request and location information. Click & Collect is currently not available.
Prices only for Meesenburg customers

Product advantages

Status display via illuminated ring
Operation via touch display with authorization code
Acoustic signalling of alarms or faults with the function orientation signal
Product properties
Product properties

Description

Für die Anwendung mit und ohne Zeitverzögerung, mit 4 Draht-Bus-Verkabelung in Hi-O Technology. Ersetzt bisherige Fluchttür-Steuerungs-Systeme mit Komponenten aus Not-Auf-Auslösung, Schlüsselschalter und beleuchtetes Piktogramm.

Hinweis:
Zur Montage in uP Schalterdosen für Lichtschaltersysteme.
Mit ePED® Interface für Verriegelungen zum Einbau in Verteilerdosen.

Product properties
technical data
Power consumption 24 V DC: 300 mA
Control function: Yes, Hi-O Technology
Operation and display function: Yes, integrated
Power supply: No, external power supply required
Connection: 4-wire bus cabling
Time delay: Yes (optional)
Illuminated indicator sign: Yes, through the integrated touch display
Display of release delay: Yes
Emergency stop switch: Yes, by operating the display unit
Control element: By code and function areas on the touch display
Commissioning: Configuration via integrated touch display
Required power supply: 24 V (±15 %) DC SELV
Operating temperature range: –10 °C – +55 °C
Application: For indoor use
Protection class: IP30 (when fully assembled)
Mounting: In switch boxes >= 62.5 mm deep
Dimensions: 113 x 99 x 29 mm (H x W x D)
Colour: Black (housing)
Inputs: 2
Outputs: None
Number of bus addresses: 3
Emergency door terminal for bidirectional escape route    Yes
Tested according to    EltVTR; DIN EN 13637:2015
Direction
left right
Voltage (electric strike)
9 - 24 Volt
wide
52 mm
Depth
20 mm
Height
59 mm

Manufacturer contact information

ASSA ABLOY Sicherheitstechnik GmbH
Bildstockstraße 20
72458 Albstadt
Deutschland
Tel.: +49 74311230
albstadt@assaabloy.com
chevron-leftAlertBrowse fileDownload fileFileImagePdfPdfWordTextExcelPowerpointArchiveCsvAudioVideoSpinnerCalendarSort NoneSort ASCSort DESCReturn arrowVisibleVisibleHelmetSkrewWorker